8.2.3 Start Status Codes

Whenever you try to start AcuServer, either by the "acuserve -start" command or the ACP, AcuServer returns a status to the operating system indicating success or failure. The way to get this status depends on your shell. When using the Bourne shell (or a compatible shell), echo $? to see the return status of any program executed from the shell.

The return codes are as follows:

Return Code Description

0

Success. AcuServer is running.

1

Invalid argument.

2

Missing license.

3

Expired license.

4

Unable to open the error log file.

5

Unable to open the configuration file (writable by other than root).

6

Unable to open the AcuAccess file (missing or writable by other than root).

7

Unable to create a child process.

8

Too many servers running.

9

Unable to create a socket, but the socket is used by something other than AcuServer.

10

AcuServer is already running on this port.